Supplied with Two Filters (Na and K), Inbuilt Air Supply Unit, Atomizer Tube,
Sample Beaker (06 Nos.), Gas Lighter, LPG
Tube, Power Cord, ANALABsafe software, USB Interface Cable,
Operational & Instruction Manual with SOP, Calibration Test
Certificate (Without Traceability Document) and Warranty Card.
Technical Specification:
Element Range : Na, K, & Li : 0.1-200 ppm, Ca : 15-300 ppm, Ba : 50-3000 ppm
Sensitivity : Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm, Ba: 50 ppm
Filter Selection : Automatic by soft touch key
Resolution : 0.1 ppm
Detector : Silicon Photodiode
Linearity : Better than 2%
Unit of Measurement : ppm/ mg/l/ meq/l and mmol/l
Reproducibility : <1% Coefficient of Variation (CV) for 20 consecutive samples using 10 ppm Na set as
maximum standard “Curve Fitting Accuracy<1% error when 3 ppm Na/K and 5 ppm Li are sets maximum standards.
Quick Calibration Facility : With Highest standard
Method : 40 method with View, Print & Delete facility
Calibration : Up to 05 standards per Element with Curve Fitting Software in built with
Instrument. (Automatic calculation of curve coefficient)
Calibration of Sample : Multi elements in single aspiration OR one by one.
Analysis of Sample : Multi elements in single aspiration OR one by one.
Ignition System : Automatic
Auto LPG Shut-off at Power Off : Safety feature in case of sudden power failure
Flame Type : LPG & Dry Oil Free Air
Auto Flame ON / OFF Detection : Yes Audio and Visual Alarm
Display : 20 x 4 Line Alphanumeric LCD with Backlit
Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
Gas Control : Adjustable with Regulator
Atomizer : Axial Flow Type
Air Supply Unit (In-built) : Consist of Air Compressor, Pressure Gauge, Pressure Regulator, Moisture
Filter, PU Tube (2 Meters) and Air filter with moisture absorbent catalyst
Error Messages : “LPG On/Off”, “Wrong Standard”, “Home Detection”, “Memory Full”, “Flame
Not ON”, “Value Out of Limit”, “Do Warm-up” & “In Correct Standard”.
Calibration Data Storage : Non Volatile Memory which can store, print & view last calibration data, calibration date
& time, company name, calibration done by, calibration standard etc.
Searching of data : with record number, batch number, Date and by scrolling
Report Formation : As per GLP Compliance
Analysis Data Storage : More than 1500 analysis data can be stored with corresponding calibration data with
batch number, users name, sample name, instrument serial number, instrument ID,
model number, sample type, display of calibration standard, calibration date& time,
Analysis date & time, display of reading in ppm etc. Secondly, analysis data can print
directly from analysis mode without saving analysis data in instrument.
21 CFR Part-11 Compliance : ● In-built with system
● 1 Admin and 7 users with different Login ID & Password.
● Audit trail can store more than 5000 lines in system itself.
● Audit trail includes action taken, date & time, action taken by whom.
● Audit trail can be transfer to PC through ANALABsafe software and
can print on 40 / 80 column dot matrix printer for record.
● Once Audit trail transfer to the PC or Printer, automatically system
will delete Audit trail records and before final deleting, the system
will give warning twice.
Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
PC Interface : USB Type - B
Printer : 40 / 80 Column Dot Matrix Printer (Printer required to procure optionally)
PC Connectivity : By USB Interface Cable with Driver, ANALABsafe software to transfer Analysis data in
GLP format, Calibration data and Audit trail from Instrument to PC in non-editable
format and is password protected.
Power Supply : 230 VAC ± 10%, 50 Hz