Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, ANALABsafe software, USB Interface Cable, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.
Technical Specification:
Conductivity Range : 0 to 20.00, 200.0, 2000 µS/cm; 2 to 20.00, 200.0 mS/cm
(Range value change depending upon cell selection)
Conductivity Resolution : 0.001,0.01,0.1 µS/cm & 0.001, 0.01, 0.1mS/cm
TDS Range : 0 to 10, 100, 1000, 10000, 100000 ppm (Depending upon Cell Constant & TDS factor)
TDS Resolution : 0.001, 0.01, 0.1 ppm & 0.001, 0.01 ppt (1ppt=1000ppm)
Resistivity Range : 0 to 20.0, 200.00, 2000 KO, 2.00 to 20.0, 200 MO
Resistivity Resolution : 0.001, 0.01K & 0.1 O
Salinity : 0.01 to 80000.0 ppm NaCl
Temperature Range : 0 to 130°C
Temperature Resolution : 0.1°C
Temperature Compensation : Auto / Manual
Temperature Coefficient : 0-10.000 % per °C (Adjustable) Five – One Per Range
Temperature Calibration : Onsite by users with in-built software
Display : 20 x 4 Line Alphanumeric Backlit LCD.
Range Selection : Auto / Manual
Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS.
Reading : Conductivity at actual temperature and at 25°C, TDS, Resistivity & Salinity with scrolling
display
Number of Range : Five
Calibration Standard : Five Conductivity & TDS Standard - One Per Range
Calibration Factor : Five – One Per Range
Error Messages : “Wrong Standard / Cell”, “Cell Short”, “Cell Open”, “Try Upper Range”, “Try
Lower Range” & “Temperature Probe Error”.
Suitable Cell Constant : 0.1,0.5 & 1.0 K
Adjustable Cell Constant : 0.09 to 0.11 K, 0.452 to 0.55 K & 0.90 to 1.1 K
Password Protection : Date & Time, Calibration Mode & Delete Stored Analysis Data (Different
Passwords)
Conductivity to TDS Conversion Factor : 0.40000 to 1.00000 (Adjustable)
Calibration Data Storage : Non Volatile Memory which can store, print & view with calibration date & time, cell
constant, calibration range, standard conductivity solution, measured conductivity at
25°C & actual temperature, calibration factor, instrument serial number, instrument ID,
model number etc.
Report Formation : As per GLP Compliance.
Analysis Data Storage : More than 1000 analysis data can be stored with corresponding calibration date &
time, company name, sample name, sample batch/ID, conductivity at 25°C and
conductivity at actual temperature, conductivity to TDS conversion factor, TDS,
resistivity, salinity, instrument serial number, instrument ID, model number etc.
Secondly, analysis data can print directly from analysis mode without saving analysis
data in instrument.
Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
PC Interface : USB Type - B
Printer : 40 / 80 Column Dot Matrix Printer (Printer have to procure optionally)
PC Connectivity : By USB Interface Cable with Driver, ANALABsafe software to transfer Analysis data in
GLP format, Calibration data and Audit trail from Instrument to PC in non editable
format and is password protected.
Power Supply : DC Adaptor