MIST SHOWER BOOTH

Mist Shower Booth supplies a fine, low volume misting "fog" intended to affix loose powder on the surface of the
occupant's protective clothing (PPE). This helps prevent any hazardous particulate from becoming airborne when
degowning.


Mist Shower Booth is installed at exit of clean room where Hazardous Product like Onco Drugs, Harmonal Injectible,
Strile products and likewise.

The Misting Booth is a contamination control device for the
respiratory protection from inhalation of these hazardous
products to the operator during the degowning process.

Read more

GENERAL SPECIFICATION

Sr. No.  Item Description
1. MOC SS 304 / SS
316 / SS 316L combination of SS 304 & SS 316
as per –
ASTMA
2. Two stage filtrations

EU6–Fine Filter (efficiency 95% down to 5 micron)
EU-14 HEPA - Filter Supply (99.999% down to 0.3 micron)

3. Operating Condition

ISO
class 5 (ISO 14644 –
I : 2015 (E)]

4. General Specifications

SS304 door with double wall flush view panel & door closer
SS 304 water shower nozzles
LED Light fixture
SS 304 Drain system
SS 304 DOP test port
Solenoid Valve for Air & water control
Spray gun for manual
operate (Water / Air) for cleaning
Water proof door release switch & Emergency switch inside
MIST Shower
Control System to ensure that both the doors cannot open at
the same time & to ensure that both the doors will be locked
during the process
Timer setting for mist shower operation
Straight Entry – Straight Exit / 90 0 door ope ning
Automatic as well as manual Mode


Motor Blower
Operating Conditions
Air Cleanliness
Air Velocity
Air Flow
Noise Level
Vibration Level
Powder coated Mild Steel/ SS 304 or combination of both
EU 14 HEPA Filter Supply (99.999%) down to 0.3 micron)
EU 6 - Fine Filter - (efficiency 95% down to 5 micron)
Dynamically balanced with suitable rating and size
LED Lights with milky white diffuser
5/15 Amp switch socket for external equipment
SS 304 / Aluminum (Anodized) Air Nozzle
Electromagnetic Inter locking system to ensure that both the doors cannot open at the same time
& to ensure that both the doors stay locked during the time of air flow
SS 304 Sandwiched doors with toughened glass view panel with proper gasketing
ISO class 5 (ISO 14644-1: 2015 (E)]
0.45 + 0.05 mps.
Vertical - Horizontal
Less than 67dB on scale 'A' when ambient is not greater than 55 dB on scale 'A'
Minimum
1.
2.
3.
4.
3 VISHWAKARMA

Vishwakarma Engineering

Vishwakarma Engineering
Manufacturer
India

Primary focus area

Project Management / Consultants

Add to Favourite
Book a Demo