Biological Safety Cabinet Class II Type A2 provide personnel, environmental and product protection. Air flow is drawn around the operator into the front grill of the cabinet, which provides personnel protection. In addition, the downward laminar flow of HEPA-filtered air provides product protection by minimizing the chance of cross-contamination along the work surface of the cabinet. Because cabinet air has passed through the exhaust HEPA filter, it is contaminantfree (environmental protection).
GENERAL SPECIFICATION
S. No. | ITEM | DESCRIPTION |
1. | MOC | SS 304 / SS 316 / SS 316L combination of SS 304 & SS 316 as per - ASTMA |
2. | Three stage filtrations | EU4 - Prefilter ( arrestance 85% down to 10 micron) EU14 - HEPA Filter- Supply (99.999% down to 0.3 micron) at supply / exhaust position return air filter. EU6 - FINE Filter (efficiency 95% down to 5 micron) |
3. | Motor Blower | Dynamically balanced with suitable ratings and size. ON / OFF switch Digital pressure gauge SS 304 DOP Test Port |
4. | Air Cleanliness Air Velocity Air Flow Noise Level Vibration Level |
ISO class 5 (ISO 14644-1: 2015 (E)] 0.45 + 0.05 mps. Vertical - Recirculatory Less than 65 dB on scale ‘A’ when Ambient is not greater than 55dB on scale ‘A’ Minimum |
5. | Options & Accessories | Audio Visual Alarm indicating condition of HEPA Filters Flame Proof Fitting U.V. Light with Hour meter Vishwakarma Industries Data Management 21 CFR Part 11 compliance Software. |