The i-Series brings together all the functions required for LC analysis in an integrated form. With its space-saving design,
which is only 410 mm wide, three units can be installed on a laboratory bench compared to only two comparable
instruments from other companies. The instrument footprint does not change even if another detector is installed
System Monitoring via Smart Devices
Window on a Smartphone
In addition to the UV-visible (UV/VIS) absorbance detector or
photodiode array (PDA) detector included as standard, a flfluorescence
detector or differential refractive index detector can be added.
Large-Capacity Column
Oven Supports Up to 90°C
The Forced-air circulation method
enhances column temperature
stability. Maximum operating
temperature of 90°C allows
high-temperature analyses such as
sugar analysis. Moreover, three 300
mm long columns or six 100 mm long
columns can be accommodated.
Quaternary Solvent
Delivery Unit
A 10 μL micro plunger ensures
accurate quaternary gradient
delivery. Optional reservoir switching
valve further extends the solvent
selection to seven so that the solvent
for the flflow path rinsing can be set.
The UV/VIS detector and the PDA detector employ dual-temperature
control (TC-Optics and flflow cell) and provide measurements with a
stable baseline hardly affected by room temperature flfluctuation.
Excellent reproducibility for injection volumes less than 1 μL,
wide linearity range and ultra-low carryover (<0.0025%) improve
the reliability of data, especially for analyses of precious
biological samples and direct analyses of concentrated samples.
Compact Footprint
The i-Series brings together all the functions required for LC analysis in an integrated form. With its space-saving design,
which is only 410 mm wide, three units can be installed on a laboratory bench compared to only two comparable
instruments from other companies. The instrument footprint does not change even if another detector is installed.
After analysis is complete, the auto
shutdown function minimizes power
consumption in standby mode and
can reduce power consumption by at
least 95% compared to normal
standby mode.
A 14-second injection cycle maximizes the number of samples
that can be processed.
Moreover, a total of 1536 samples can be accommodated in
right and left sample racks.
A direct access mechanism on sample racks allows the
user to place the sample on racks that are not
involved in sample injection even during analysis.
Furthermore, racks can be shared by multiple
analysts, without interrupting the analysis of samples
placed by others. Overall, this function enhances
work effificiency.
System status and chromatograms can be viewed
remotely from smart devices and home computers.
Situations can be checked without needing to visit
the laboratory.
70 MPa (0.0001 to 3 mL/min)
44 MPa (3.0001 to 5 mL/min)
22 MPa (5.0001 to 10 mL/min)