HPLC 2060 Integrated System

The i-Series brings together all the functions required for LC analysis in an integrated form. With its space-saving design,

which is only 410 mm wide, three units can be installed on a laboratory bench compared to only two comparable

instruments from other companies. The instrument footprint does not change even if another detector is installed

System Monitoring via Smart Devices

Window on a Smartphone

In addition to the UV-visible (UV/VIS) absorbance detector or

photodiode array (PDA) detector included as standard, a flfluorescence

detector or differential refractive index detector can be added.

Large-Capacity Column

Oven Supports Up to 90°C

The Forced-air circulation method

enhances column temperature

stability. Maximum operating

temperature of 90°C allows

high-temperature analyses such as

sugar analysis. Moreover, three 300

mm long columns or six 100 mm long

columns can be accommodated.

Quaternary Solvent

Delivery Unit

A 10 μL micro plunger ensures

accurate quaternary gradient

delivery. Optional reservoir switching

valve further extends the solvent

selection to seven so that the solvent

for the flflow path rinsing can be set.

The UV/VIS detector and the PDA detector employ dual-temperature

control (TC-Optics and flflow cell) and provide measurements with a

stable baseline hardly affected by room temperature flfluctuation.

Excellent reproducibility for injection volumes less than 1 μL,

wide linearity range and ultra-low carryover (<0.0025%) improve

the reliability of data, especially for analyses of precious

biological samples and direct analyses of concentrated samples.

Compact Footprint

The i-Series brings together all the functions required for LC analysis in an integrated form. With its space-saving design,

which is only 410 mm wide, three units can be installed on a laboratory bench compared to only two comparable

instruments from other companies. The instrument footprint does not change even if another detector is installed.

After analysis is complete, the auto

shutdown function minimizes power

consumption in standby mode and

can reduce power consumption by at

least 95% compared to normal

standby mode.

A 14-second injection cycle maximizes the number of samples

that can be processed.

Moreover, a total of 1536 samples can be accommodated in

right and left sample racks.

A direct access mechanism on sample racks allows the

user to place the sample on racks that are not

involved in sample injection even during analysis.

Furthermore, racks can be shared by multiple

analysts, without interrupting the analysis of samples

placed by others. Overall, this function enhances

work effificiency.

System status and chromatograms can be viewed

remotely from smart devices and home computers.

Situations can be checked without needing to visit

the laboratory.

Read more

70 MPa (0.0001 to 3 mL/min)

44 MPa (3.0001 to 5 mL/min)

22 MPa (5.0001 to 10 mL/min)

Add to Favourite